毕业设计任务书——范本

来源:m.fanwen118.com时间:2022.12.6

吉 首 大 学

本科生毕业设计任务书

题目名称 安溪铁观音系列茶叶包装设计 学生姓名 张志华 学号 20084151055 学 院 美术学院

专业年级 视觉传达 2008级

指导教师 彭涛 职称 副教授

填写时间 20xx年11月16

毕业设计任务书范本

(1)商品包装设计(2)书籍装帧设计 (3)广告设计 (4)CI设计[2]题目来源:(1)教师科研课题 (2)生产实际题 (3)学生自选题

毕业设计任务书范本

毕业设计任务书范本


第二篇:土木毕业设计任务书范本 27200字

桂林理工大学本科毕业设计·论文

目录

桂林市XX办公楼设计任务书 .......................................错误!未定义书签。

工作计划........................................................................ 1 读书笔记........................................................错误!未定义书签。

开题报告....................................................................... 12 外文翻译........................................................错误!未定义书签。

阶段总结....................................................................... 23 毕业实习报告 ....................................................错误!未定义书签。

毕业设计总结 ................................................................... 29

I

桂林理工大学本科毕业设计·论文

桂林理工大学

本科学生毕业设计(论文)

任 务 书

系( 院 ): 土木工程系

课题名称: 桂林市市政办公楼设计

专业(方向): 土木工程(工民建)

班 级: 土木应用05-2

学生姓名: 辛荣超 学号: 3050210623

指导教师: 罗小平 职称: 讲师

下发日期: 2009.3

桂林理工大学教务处制

II

桂林理工大学本科毕业设计·论文

土木毕业设计任务书范本

III

桂林理工大学本科毕业设计·论文

土木毕业设计任务书范本

桂林理工大学本科毕业设计·论文

土木毕业设计任务书范本

V

桂林理工大学本科毕业设计·论文

土木毕业设计任务书范本

指导教师: (签字)

教研室主任: (签字)

系(院)主任: (签字)

VI

桂林理工大学本科毕业设计·论文

工作计划

毕业设计是总结我们学生在校期间的学习成果,是学生综合运用所学的基础知识、专业知识和基本技能进行建筑、结构、施工设计的重要实践过程。通过毕业设计的实践,学习、掌握和提高综合应用所学知识进行分析问题和解决工程实际问题的能力。

根据毕业设计任务书的要求,在指导老师的指导下,结合自身的实际情况,我在开始设计时做了一系列的准备。

毕业设计的课题是桂林市市政综合办公楼的建筑和结构设计。要求通过实践工程的结构设计,初步掌握其设计原则、方法和步骤,并获得设计技能的基本训练。结构布置要求荷载传递直接、受力明确,还需考虑整个建筑物的平面和竖向刚度及整体性,尽量减少扭转效应,在结构布置的基础上深入考虑在竖向荷载和水平荷载作用下,结构体系之间协同工作的程度,合理的确定结构或构件的计算简图。通过必要的计算和结构处理,使结构构件及其连结的节点满足强度、刚度、裂度的要求,最终把结构布置和构件设计准确地反映到施工图上。

以下表格为具体的工作计划和步骤

土木毕业设计任务书范本

1

桂林理工大学本科毕业设计·论文

土木毕业设计任务书范本

2

桂林理工大学本科毕业设计·论文

读书笔记

承载力极限状态计算规定

新规范把建筑结构的安全等级分为三个级别,但由于增加了由永久荷载效应控制的荷载组合,提高了其中的永久荷载系数,因此取消了旧规范中屋架、托架、恒载为主的轴心受压柱、小偏心受压柱安全等级应提高一级,预制构件施工阶段安全等级可降低一级的规定;

承载力极限状态设计表达式仍为:γ0S≤R;

确定结构重要性系数γ0时,规定了设计使用年限为100年及以上的结构构件

与安全等级一级相当,设计使用年限为50年的结构构件与安全等级二级相当,设计使用年限为5年及以下的结构构件与安全等级三级相当。

荷载效应组合设计值S按基本组合或偶然组合进行;

按照新的《建筑结构荷载规范》GB50009的规定,对于基本组合,应取下列最不利值:

1)由可变荷载效应控制的组合:

S=γGSGk+γQ1SQ1+∑ni=2γQiψciSQik

对于一般排架、框架结构可简化为:

S=γGSGk+γQ1SQ1

S=γGSGk+ 0.9∑ni=1γQiSQik

2)由永久荷载效应控制的组合:

S=γGSGk+∑ni=1γQiψciSQik

γG应取1.35,参与组合的可变荷载仅限于竖向荷载;偶然组合与旧规范相

同。

正常使用极限状态验算规定

新规范规定对于正常使用极限状态,结构构件应分别按荷载效应的标准组合、准永久组合或标准组合并考虑长期作用影响采用下列极限状态设计表达式为:S≤C;

标准组合即旧规范中的短期效应组合,准永久组合即旧规范中的长期效应组合;

受弯构件的最大挠度计算应按荷载效应的标准组合并考虑荷载长期作用影响,与旧规范相同;

结构构件正截面裂缝控制等级仍分为三级,其中二级裂缝控制的构件,旧规

3

桂林理工大学本科毕业设计·论文

范在荷载效应标准组合下拉应力不超过αctγftk的规定改为不超过ftk,而一级和三级裂缝控制的构件与旧规范相同;

新规范中裂缝控制等级及最大裂缝宽度限值改由环境类别和结构类型确定,与旧规范按构件类型、钢筋品种和室内外环境分类的规定不同。

耐久性的规定

新规范关于耐久性设计的内容有两种形式:

1) 特别增加了耐久性规定这一节,直接规定环境的分级方法以及各类环境对结构混凝土耐久性的基本要求等;

2) 对于分散在各章节中的影响混凝土耐久性的有关条款作必要的修改,如加大混凝土保护层的厚度,在“构件”和“构造”章节中表达与耐久性有关的构造措施等;

影响耐久性的最重要因素是环境,新规范把环境分为五类,与模式规范MC-90基本相同,环境是耐久性设计的主要依据;

影响耐久性的另一个重要因素是混凝土本身的质量,而混凝土的质量与混凝土强度等级、水灰比、水泥用量密切有关,此外混凝土中的氯离子含量和碱的含量也对耐久性有重大影响,新规范为保证结构混凝土的耐久性,对使用年限50年和100年的混凝土结构的混凝土质量提出了规定;

应该指出,新规范只是采用宏观控制的办法,还不能定量地确定结构的耐久性。

混凝土结构的环境类别

新规范取消了旧规范中的C7.5级和C10级低强度混凝土,增加了C65、C70、C75和C80级高强度混凝土,标志了我国混凝土技术的进步和施工、设计水平的提高;

新规范对结构混凝土的强度等级提出了最低要求,是下限值,不是最佳值; 随着混凝土强度等级的提高,强度价格比迅速提高,采用较高强度的混凝土,对柱、墙、基础等受压为主的构件以及预应力构件有显著的经济效益;受弯构件选用C20-C30,受压构件选用C30-C40,预应力构件选用C30-C50,高层建筑底层柱选用C50或以上,不仅承载力得到了提高,抗剪及裂缝控制性能也随之提高。 混凝土的设计参数

混凝土的强度等级只是混凝土力学性能的一个基本标志,作为其代表值的立方体抗压强度标准值fcu,k也不具备直接作为设计参数的条件,只能作为确定设计

参数的依据;混凝土的设计参数主要有:轴心抗压强度fc、轴心抗拉强度ft、弹

4

桂林理工大学本科毕业设计·论文

性模量Ec、剪变模量Gc、泊松比ν、线膨胀系数αc以及疲劳强度修正系数γρ;新规范删除了旧规范中的弯曲抗压强度fcm,改用轴心抗压强度fc乘以反映高强混

凝土特性的降低系数α1来表示,理由如下:

1)与国际接轨;

2)协调正截面承载力的计算;

3)简化计算;

新规范调整了轴心抗压强度标准值、轴心抗拉强度标准值与立方体抗压强度标准值之间的关系式;为提高安全度,混凝土材料分项系数由1.35提高为1.40;弹性模量、剪变模量、泊松比、线膨胀系数以及疲劳强度修正系数等与旧规范一致,仅补充了C65-C80高强混凝土相应的参数。

正截面承载力计算

混凝土弯曲抗压强度不是通过直接量测得到的强度,只是一个概念上的强度。混凝土正截面承载力设计时,在弯矩M和轴力N的共同作用下,由纯弯曲、大偏心受压、小偏心受压到轴心受压是一个连续渐变的过程,旧规范对受弯状态为主计算取弯曲抗压强度,而对受压状态为主的计算取轴心抗压强度,从概念上和计算上不能协调,而取一个参数就容易多了。

简化计算

取消弯曲抗压强度以后,有关混凝土抗压方面的设计参数只有一个轴心抗压强度,从概念上到计算上都得到了简化。反映不同受压状态特征的抗压强度(如弯曲抗压强度、局部抗压强度等)可以通过计算公式的调整加以反映,完全可以用简单的形式确切地反映应有的规律。

新旧规范对比

轴心抗压强度

fck=0.88×0.76 fcu,k (旧规范)

fck=0.88α1α2fcu,k (新规范)

系数0.88是考虑实际结构中的混凝土与试块混凝土强度之间的差异等因素而确定的修正系数;

α1为轴心抗压强度与立方体抗压强度的比值,α2为混凝土脆性系

ft=0.88×0.26 (fcu,k)2/3 (旧规范)

ft=0.88×0.395α2 (fcu,k)0.55(1-1.645δ)0.45 ( 新规范)

系数0.88是考虑实际结构中的混凝土与试块混凝土强度之间的差异等因素而确定的修正系数;α2为混凝土脆性系数

5

桂林理工大学本科毕业设计·论文

板结构

混凝土矩形板的长向、短向跨度比值大于3时,按单向板设计,简支或连续的单向板可用解析法或弯矩分配法计算;

混凝土矩形板的长向、短向跨度比值小于3大于2时,也可按单向板设计,但沿长向跨度应配一定的构造钢筋;

混凝土矩形板的长向、短向跨度比值不大于2时,按双向板设计,形状规则、支撑条件和荷载形式简单的双向板可以利用计算图表查到,一般的板则需用有限元法程序进行分析 。

塑性分析方法

在混凝土结构分析中经常采用的塑性分析方法有考虑塑性内力重分布的弯矩调幅法、塑性极限分析方法中的塑性铰线法和条带法等;钢筋混凝土连续梁和连续单向板宜采用考虑塑性内力重分布的弯矩调幅法,框架、框架剪力墙结构以及双向板等也可对支座或节点的弯矩进行调幅,并确定跨中弯矩,对于直接承受动力荷载的结构、要求不出现裂缝或对裂缝控制较严的结构、处于严重侵蚀性环境中的结构以及配置延性较差的钢筋的结构不得采用塑性内力重分布的方法;承受均布荷载的周边支承的双向矩形板可采用塑性铰线法或条带法进行承载能力极限状态设计。

采用塑性分析方法设计时,同时应满足正常使用极限状态的要求。 单筋矩形截面

在单筋矩形截面计算公式中,新规范只是用α1f c代替了旧规范中的f cm ,其他保持不变:

α1f cbx=fyAs

M≤ α1f cbx(h0-0.5x)

适用条件:

x≤ξbh0

sA≥ρminA

也可采用下列形式的公式计算:

α1f cξbh0=fyAs

M≤ α1f cb h02 ξ( 1-0.5 ξ )

= αsα1f cb h02

双筋矩形截面

同单筋矩形截面一样,在双筋矩形截面计算公式中,新规范也是用α1f c代

6

桂林理工大学本科毕业设计·论文

替了旧规范中的f cm ,其他保持不变: α1f cbx=fyAs-fy’As’

M≤ α1f cbx(h0-0.5x)+fy’As’ (h0-as’) 适用条件: x≤ξbh0

x≥2as’

也可采用下列形式的公式计算: α1f cξbh0=fyAs-fy’As’

M≤ α1f cb h02 ξ( 1-0.5 ξ ) +fy’As’ (h0-as’)

= αsα1f cb h02 +fy’As’ (h0-as’) T形截面

同单筋矩形截面、双筋矩形截面一样,在T形截面计算公式中,新规范也是用α1f c代替了旧规范中的f cm ,其他保持不变;T形截面仍需先确定受压翼缘的宽度,再分为第一类和第二类两种情况分别按不同的计算公式进行设计,具体公式详见规范,不一一列出。 受弯构件斜截面承载力计算

新规范对斜截面承载力计算的修改和补充如下:

1) 与国外规范和国内其他行业的规范相比,旧规范中斜截面抗剪承载力计算公式的可靠度水平较低,为提高抗剪承载力的可靠指标,新规范适当降低了计算公式中的一些系数和参数;

2) 为使公式能适用于高强混凝土,在截面尺寸控制条件中加入了混凝土强度影响系数βc;并且把旧规范斜截面承载力计算公式中的混凝土轴心抗压强度 fc 改用混凝土轴心抗拉强度 ft 表达; 3) 新规范取最小配箍率ρ高;

4) 增加了无腹筋板类受弯构件的斜截面计算公式; 5) 增加了圆形截面构件的斜截面计算方法(略);

6) 增加了矩形截面柱双向受剪的框架柱的斜截面计算方法(略)。 有腹筋梁斜截面承载力计算公式

有腹筋梁的斜截面承载力计算公式: 1)矩形、T形和工形截面的一般梁

Vcs≤0.7ftbh0+1.25fyvAsvh0/s+0.8fyAsbsinα

7

sv,min

=0.24ft/fyv,比旧规范的0.02fc/fyv略有提

桂林理工大学本科毕业设计·论文

Vcs≤0.07fcbh0+1.5fyvAsvh0/s+0.8fyAsbsinα (旧规范) 2)集中荷载作用下的独立梁

Vcs≤(1.75/(λ+1))ftbh0+1.0fyvAsvh0/s+0.8fyAsbsinα

Vcs≤(0.2/(λ+1.5))fcbh0+1.0fyvAsvh0/s+0.8fyAsbsinα(旧规范) 矩形、T形和工形截面的受弯构件,其受剪截面应符合下列条件: 当hw/b≤4时 V≤0.25βcfcbh0

V≤0.25fcbh0 (旧规范) 当hw/b≥6时 V≤0.2βcfcbh0

V≤0.2fcbh0 (旧规范) 无腹筋板类受弯构件的斜截面计算

无腹筋板类受弯构件的斜截面计算公式如下: V≤0.7βhftbh0

其中βh为截面影响系数, 取βh=(800/h0)1/4

当h0<800mm时,取800mm; 当h0>2000mm时,取2000mm;

实际上当板厚小于800mm时可不考虑受剪承载力的提高,当板厚大于2000mm时,抗剪承载力还将下降,但目前实验数据不够,新规范未作规定,可在板的中部布置构造钢筋网,能较好地改善其抗剪性能。 轴心受压构件构件承载力计算

由于新规范在受弯构件和偏心受压构件的承载力计算公式中,把fcm(=1.1 fc)降低为(0.94~1.0)fc,因此偏心受压构件的安全储备有所提高,为了与偏心受压构件的承载力保持相近的可靠度,新规范在轴心受压构件的承载力计算公式中增加了一个0.9的系数:

N≤0.9φ(fcA+fy’As’)

因为增加了0.9的系数,新规范取消了关于“屋架、托梁的受压腹杆的安全等级应提高一级”的规定。

对于配置螺旋式或焊接环式间接钢筋的轴心受压构件,其承载力计算公式也增加了系数0.9,并且在间接钢筋承载力一项中还增加了一个折减系数α(0.85~1.0),考虑由于采用高强混凝土,间接钢筋对受压承载力增大的影响有所减弱: N≤0.9(fcAcor+fy’As’+2αfyAss0 ) 偏心受压构件承载力计算

新规范规定偏心受压构件不论偏心大小都必须考虑附加偏心距,并规定附加

8

桂林理工大学本科毕业设计·论文

偏心距ea为20mm和偏心方向截面尺寸的1/30两者中的较大值,而旧规范则在大偏心时不考虑附加偏心距,仅在小偏心情况下才考虑,并取 ea=0.12(0.3h0- e0)。

新规范对于二阶效应的问题,即竖向荷载在有侧移框架中引起的附加弯矩问题,除了继续给出与旧规范相同的考虑附加偏心距的ε-l0法之外,增加了考虑二阶效应的弹性分析方法。

不对称配筋矩形截面偏心受压承载力计算公式基本保持不变,仅用α1fc代替fcm。

对称配筋矩形截面偏心受压承载力计算公式中,对小偏心近似公式的系数作了调整。

考虑附加偏心距的η-l0法

新规范关于偏心距放大系数ε的计算公式基本上与旧规范相同: ε=1+(l0/h)2δ1δ2/(1400ei/h0) 其中: δ1=0.5fcA/N,δ2=1.15-0.01l0/h,ei=e0+ea

新规范规定当l0/h≤5(l0/i≤17.5)时可取ε=1,旧规范则为l0/h≤8时可取ε=1。

对于计算长度l0的规定,基本与旧规范相同。如:现浇楼盖框架结构底层柱取l0=1.0H,其余各层柱l0=1.25H。但新规范对水平荷载产生的弯矩设计值占总弯矩设计值75%以上时,可按下面两式计算框架柱计算长度,并取较小者: l0=〔1+0.15(ψu+ψl)〕H l0=(2+0.2ψmin)H

其中: ψu、ψl为柱的上端和下端节点处交汇的各柱线刚度之和与交汇的各梁线刚度之和的比值; ψmin为ψu、ψl的较小值;H为柱的高度。 不对称配筋矩形截面偏心受压承载力计算公式

矩形截面大偏心(2as’≤x≤ξbh0)受压承载力计算公式如下: N≤α1fcbx+fy’As’-fyAs

Ne ≤α1fcbx(h0-0.5x)+fy’As’(h0-as’) e=εei+h/2-as

当x< 2as’时,按下式计算:

Ne’ ≤fyAs(h0-as’) e’=εei-h/2+as

矩形截面小偏心(x>ξbh0)受压承载力计算公式如下: N≤α1fcbx+fy’As’-σsAs

9

桂林理工大学本科毕业设计·论文

Ne ≤α1fcbx(h0-0.5x)+fy’As’(h0-as’) σs=fy(x/h0-β1)/(ξb- β1) 当N>α1fcbh时,应按下式验算: Ne’ ≤α1fcbh(h0’-h/2)+fy’As(h0’-as) e’=h/2-as’-(e0-ea)

对称配筋矩形截面偏心受压承载力计算公式

矩形截面大偏心(2as’≤x≤ξbh0)受压承载力计算公式如下: x=N/ α1fcb

As=As’=N(e-h0+0.5x)/[fy’(h0-as’)] e=εei+h/2-as

当x< 2as’时,按下式计算:

As=As’=Ne’/[fy’(h0-as’)] e’=εei-h/2+as

矩形截面小偏心(x>ξbh0)受压承载力计算公式如下: ξ=(N-ξbα1fcbh0)/(D+α1fcbh0)+ ξ

’b

其中:D=(Ne-0.43α1fcbh02)/[(β1-ξb)(h0-as’)] As=As=[Ne-α1fcbx(h0-0.5x)]/[fy(h0-as)]

上述公式中计算所得的As和As’均应满足最小配筋率的要求,即: As或As’应大于等于0.002A。 受压构件斜截面计算

新规范关于受压构件斜截面计算的公式形式与与受弯构件集中荷载的计算公式一样,仅增加了轴力项0.07N:

V≤(1.75/(λ+1))ftbh0+1.0fyvAsvh0/s+ 0.07N

当V≤(1.75/(λ+1))ftbh0+0.07N时,可按构造要求配置箍筋。

新规范把公式的应用范围从矩形截面扩大到矩形、T形和工字形截面,并对λ作了必要的修改。

增加了圆形截面框架柱的斜截面计算方法,即规定采用等效惯性矩原则来确定等效矩形截面的宽度和高度。按上述原则,当采用等效矩形截面时,截面宽度b=1.76r,截面有效高度h=1.6r。

增加了双向受剪的框架柱的计算方法。(略) 受拉构件承载力计算

轴心受拉承载力计算公式保持不变:

10

桂林理工大学本科毕业设计·论文

N≤fyAs

小偏心受拉承载力计算公式也保持不变: Ne≤ fyAs’(h0-as’) Ne’≤ fyAs(h0’-as)

大偏心受拉承载力计算公式中,将fcm改为α1fc即可: N≤fyAs-fy’As’- α1fc bx

Ne≤α1fc bx(h0-x/2)+ fy’As’ (h0-as’)

受拉构件的斜截面计算与受压构件类似: V≤(1.75/(λ+1))ftbh0+1.0fyvAsvh0/s-0.2N

当上式右边小于fyvAsvh0/s时,取fyvAsvh0/s=V,且要求fyvAsvh0/s不小于0.36 ftbh0

11

桂林理工大学本科毕业设计·论文

开题报告

一、毕业设计(论文)选题的依据(包括课题来源、依托的项目名称、研究或应用意义、国内外研究或应用现状,附主要参考文献)

根据桂林市城市高新区发展需要,经上级主管部门批准,拟在我市高新区兴建一座综合办公楼,以满足办公、接待、陈列、阅览等需要,同时也有利于改善和丰富高新区的环境和设施。

工程技术条件:

1、气象:

(1) 温度:最热月平均31.6℃,最冷月平均6.2℃;

夏季最高40.8℃,冬季最低1℃。

(2) 相对湿度:最热月平均73%。

(3) 主导风向,冬季多西北风,平均风速2.8m/s,夏季多东南风,平均风速

2.6m/s由全基本风压分布图查出基本风压值为0.3KN/m2。

(4) 雨雪条件:年降雨量1600mm,月最大降雨量300mm,小时最大降雨量80mm,

雨季在6至8月。

2、工程地质条件:

(1) 自然地表1m内为填土,填土下层3米厚为红粘土,再下为砾石层。红粘土允许承载力为180KN/m3,砾石层允许承载力为300KN/m3。地基为二类场地土。

(2) 地下水位:地表以下2. 0米,水质对混凝土无侵蚀。

(3) 地震设计烈度:6度;抗震等级为四级。

根据以上条件本设计选用框架结构,六层,这样能满足使用要求.

参考资料:

1、建筑结构荷载规范(GB50009—2001),

2、建筑地基基础设计规范(GB50007—2002),

3、混凝土结构设计规范(GB50010—2002),

4、砌体结构设计规范(GB50003—2001),

5、建筑抗震设计规范(GB50011—2001)

6、工民建专业毕业设计手册,武汉工业大学出版社,19xx年8月;

7、钢筋混凝土构件设计(教材)。

8、房屋建筑学(教材)。

二、设计或研究内容、预期目标及拟解决的关键问题(此部分为重点阐述内容)

12

桂林理工大学本科毕业设计·论文

对于框架结构,在结构特点方面:它是由钢筋混凝土梁,柱,节点及基础为主要框架,加上楼板,填充墙,屋盖组成的结构形式,楼板和横梁连在一起,横梁通过节点连为一体,形成承重结构,将荷载传给基础,力的传递路线比较明确。对于整个房屋全部采用这种结构形式的称为框架结构。框架可以是等跨或不等跨的,也可以是层高相同或不相同的,因房屋的使用要求不同而不同,也可能在某层抽柱或某跨抽梁,形成缺梁,缺柱的框架。墙是填充墙,仅起围护和分隔作用,所以框架结构的最大特点是承重构件与围护构件有明确分工,建筑物的内外墙处理十分灵活,应用范围很广,因此能为建筑提供灵活的使用空间。

在结构受力性能方面:框架结构构件截面较小,因此框架结构的承载力和刚度都较低,它的受力特点类似于竖向悬臂剪切梁,楼层越高,水平位移越慢,高层框架在纵横两个方向都承受很大的水平力,所以框架结构属于柔性结构,自振周期较长,地震反映较小,经过合理的结构设计可以具有较好的延性性能。因此,根据框架结构的自身特点,在进行建筑,结构设计时国际上流行采用“三统一”的原则,即“统一柱面,统一层高,统一荷载”的模式设计。统一柱面可使办公楼根据人们的需要和功能要求实行相对任意分割,不至于因建筑柱面不同而在改变使用功能上受到制约;统一层高可使楼房采光效果较好,空气流通顺畅,人员来往便利,布局安排合理,水平运输畅通无阻,有利于使用功能的互相替代;统一荷载,打破了会议室和其他部门之间的明显界限。在这个总原则的指导下,我们考虑以下几个方面的问题:

首先,在体系的选择方面:

1、 由于在发生地震时,框架柱首当其冲,一旦出现塑性铰,将危及该柱距范围

内的上层建筑,并可能引起相临柱距范围内的上层建筑连续倒塌,所以框架结构不宜采用单跨形式;且纵横两个方向的水平地震作用都由抗侧力构件承担,结构应设计成双向框架体系;

2、 框架结构的柱与梁宜上下左右贯通,不宜采用复式框架;以及砖混框—剪结

构。

3、 在填充墙的布置方面:宜采用轻质材料,且应避免形式上下刚度变化过大;

避免形成短柱;减少因抗侧力刚度偏心所造成的扭转。

其次,在建筑设计方面:

1、 要先对建筑外观,建筑面积,建筑高度,层高和室内净高进行设计;

2、 然后对局部进行设计,如地下室墙身,楼地面,顶棚,屋面,楼面,坡面及

楼梯位置,消防要求等进行设计。各部分都要按规范要求进行设计。

13

桂林理工大学本科毕业设计·论文

3、 最后要明确框架结构的抗震等级,采用规则结构以利于房屋抗震,按照“三

统一”的原则,确定柱网尺寸,确定材料及截面尺寸,以及基础的选定。 再次,在结构设计方面:

1、首先根据不同的设计要求选取不同的荷载代表值来进行承载力计算。

2、进行变形验算。

3、进行横向水平与纵向水平

最后,我们还要进行“三水准,两阶段”设计方法进行抗震设计:

1、做好“强柱弱梁”的设计

由于框架柱受轴向压力作用,其延性通常比梁的延性小,一旦框架柱先于框架梁出现塑性铰,就会产生较大的层间位移,甚至形成同层各柱上下端同时出现塑性铰的“柱铰结构”,从而危及结构承重垂直荷载的能力。

2、做好“强剪弱弯”的设计

为了防止梁端,柱端在弯曲屈服前出现脆性剪切破坏,在设计中要求做到“强剪弱弯”亦即构件的受剪承载力要大于构件弯曲时实际达到的剪力。

3、 做好“强节点弱构件”的设计,还要对节点进行抗震结构设计,要求框架节点核芯区不先于梁柱破坏。

三、研究方案(包括有关方法、技术路线、实验手段、关键技术等)

对于课题的研究将分为毕业实习,建筑设计,结构设计,毕业设计整理四个方面。毕业实习阶段收集好必要的设计原始资料,做好设计前的调查研究工作,参考同类型设计的文字及图纸资料。学习有关的国家法规及规范。建筑设计分为初步设计及施工图设计两个阶段,在此阶段将拟订建筑方案,确定建筑使用的材料及做法,确定建筑总体形状及各种尺寸,绘出平、立、剖、总平面图、详图、写出施工说明并列出门窗表。结构设计部分包括计算确定荷载,同时进行荷载分析、内力计算,进行最终结构图的绘制,结构计算采用部分手算部分电算。毕业设计整理阶段完成对给定的英文文献的翻译工作,按学校毕业设计条例及教研室实施细则整理毕业设计成果,做好毕业答辩准备工作。

设计过程将充分考虑建筑安全、经济、适用三要素,建筑设计注意与周围环境的协调,功能区组合合理。考虑建筑自身特点,着力体现出现代商务办公楼稳重和美观大方的形象特点。结构设计要求结构布置合理,结构设计经济合理。具体设计内容、施工工艺等将按照规范在施工说明及各式设计图纸中详细体现。

四、设计或研究计划进度

进度安排:

14

桂林理工大学本科毕业设计·论文

毕业设计总时间为17周:

1、毕业实习 3周

2、建筑设计部分(包括设计和出图) 3周

3、结构设计部分(包括设计和出图) 12周

4、计算成果整理 1周

5、答辩 1周

15

桂林理工大学本科毕业设计·论文

外文翻译

Building Structure

A structure is the part of a building that carries its weight, and for at least half the world’s civil engineers, structures are most of civil engineering. We should also remember that anything built is a structure. (From an aero-plane engineer’s point of view, an aero-plane also is a structure.) A structural design is the design of building structures. The building as a whole is designed by an architect, particularly in a densely populated area. For water engineers, sewage-treatment engineers, and municipal engineers, structures are not always an important part of their work though even a road or a pipe is a structure since they both carry load.

Every structural design includes the foundation design. One of the commonest foundations is that for a concrete column or a steel stanchion. It is generally designed for the same maximum load as the column, and usually is an independent (pad) foundation. Where the pads in one row become so large that they nearly touch, it is convenient to join them into a continuous ( or trip) for foundation which generally will be cheaper to dig and to concrete than the same foundations built separately as pads.

Combined footings are those in which the pads would also be so large that they nearly touch, but unlike strip footings, they may carry the load from more than one row of columns. The final development of the combined footing is the raft (or mat or matters) foundation in which all the pads are combined into one reinforced concrete slab which may vary in thickness, but is usually of the same thickness throughout its area.

The structural design itself includes two different tasks, the design of the structure, in which the sizes and locations of the main members

16

桂林理工大学本科毕业设计·论文

are settled, and the analysis of this structure by mathematical or graphical methods or both, to work out how the loads pass through the structure with the particular members chosen. For a common structure such as a building frame, many methods have been developed for analysis, so that the design and analysis will be relatively easy and may need to be performed only once or twice.

But for any unusual structure the tasks of design and analysis will have to be repeated many times until, after many calculations, a design has been found that is strong, stable and lasting. Cheapness does not enter into the quality of the design though it is important since a costly structure will probably not be built and the designer’s fee will therefore be smaller.

For the typical multi-story structure in a city, whether it is to be used for offices or dwellings, the most important member which the engineer designs is the floor—for two reasons: it repeats all the way up the building, and it has the greatest effect on the dead load of the building. The dead load, in fact, as pointed out in ‘foundations’, can be fairly exactly calculated by assuming that the floors are the only dead load.

These floors are generally of reinforced or prestressed concrete because they resist fire better than steel or wood, an important consideration for a tall building. There are two main types, the solid floor and the hollow-tiled (or ribbed ) floor. In fact, in the ribbed floor, part of the lower half of the slab is hollow, a great advantage because this concrete would not strengthen the floor but would be heavy. Ribbed floors are therefore lighter than solid floors, but it is more difficult to cast them with holes through them unless these holes are carefully planned beforehand. It is generally safe to cast a hole through a solid slab by adding a few extra bars of 12 mm diameter in the concrete all round it, though when there is time, holes should be properly designed.

17

桂林理工大学本科毕业设计·论文

For most multi-storey buildings, because of the high cost of the land in a city , the structure itself is in a very early stage of design at a time when the foundations must be designed very quickly. The building design must, however, have processed so far that at least the positions of the columns are known, and therefore the floor spans will be fixed. The probable floor thickness can then be worked out. This will vary only slightly if at all from floor to floor, and it must be calculated as closely as possible including the topping. Generally an allowance of 13 cm of dense concrete will be enough, plus 5 cm for the topping and floor surface, making 18 cm in all. The weights of beams, columns and stairs can be regarded as included in the floor thickness allowance. If the floors are to be built with hollow tiles or with lightweight aggregate, a reduction for this should be made.

The first rough calculation of the structure weight is as follows: assuming the floors are all of the same total area, and there are eight floors including one basement not suspended but resting on the soil, the total dead weight of the building including the roof will be, per m2 of building foundation, 9*18/100*2.75=4.45 tons/m2 , the weight of 1 m3 of dense concrete being assumed to be 2.75 tons/m3.To this must be added a figure for the live load. If the building is to be for housing, a live load of 190 kg/m is usually enough for the structural design of a floor and is accepted under the building by-laws of most local authorities. But these authorities never insist on the whole of this load being applied to the foundations since it is highly improbable that all the floors would be fully loaded at the same time. In any case the depth now being calculated is not subject to control by laws, and we can use any proportion of the live load which appears reasonable.

Suspended structures are among the most interesting at the moment because the first large ones were in 1966 completed in London, and possibly

18

桂林理工大学本科毕业设计·论文

other great cities. In all these structures, these columns or stanchions are made fewer and larger so as to reduce the bucking effects on them and to increase their effective length. In two that were built in London, there is only one column, in the center of the building, and this is a hollow concrete tower some 12 m square which carries the lifts, stairs, ducts, pipes and cables within it or attached to its wall. The tower may be called the core of the building and on its top is a bridge overhanging in all directions, from which high-tensile steel bars drop to carry the floors below. These bars are very thin and can be hidden in a door frame or window frame so that for such a building there need be no noticeable obstruction to sight or horizontal movement in any direction outwards from the core.

But this is only the beginning of suspended construction. If it is successful and if the world’s large cities continue to become more crowded , the idea will grow, and the 60-storey skyscrapers of New York will be tiny compared with the vast 300-storey structures of the world’s future cities.

It seems possible and even likely that the whole city may be one or a few of these vast buildings, carried on pairs of towers 1,000 m high joined by lightweight bridge structures, possibly suspension bridge. To reduce sway and buckling, the columns will be massive, probably not less than 30 m square, and the floors will hang from the bridges by thin high-tension steel suspenders in the same way as a suspension bridge deck hangs from its cables.

建筑结构

结构物是建筑物的一部分,它支承建筑物的重量。对于世界上至少半数以上的土木工程师来说,结构物大部分是土木工程结构。我们也必须明确: 任何建造的东西都是一个结构物(从飞机工程师的观点来看,飞机也是一个结构物)。结构物可以一所住宅,可以是埃及的金字塔,安第斯山的耶稣雕像,或者是水濑建造的横贯加拿大河流的堰坝。一座房屋建筑物是一个有屋顶的结构物,而土木

19

桂林理工大学本科毕业设计·论文

工程结构设计的很大一部分就是房屋建筑结构的设计。建筑物作为一个整体来说,是由建筑师设计的,在人口稠密地区更是如此。对于给水工程师、污水处理工程师和市政工程师来说,结构物并不总是他们工作中的重要部分,但是一条道路或一条管道也是结构物,因为这两者均支承荷载。

任何结构设计都包括基础设计。最常见的基础之一是混凝土柱或钢支柱的基础。这种基础一般按柱的最大荷载设计通常为独立(单柱)基础,当排成一列的单柱基础太大,以致几乎互相接触时,最好把它连接起来形成连续(条形)基础。连续基础的土方开挖和混凝土浇灌费用比分别做成数个单柱基础的同样基础要低廉。

联合基础就是其中的单独基础也会大得几乎相互接触的一种基础,但它与条形基础不同,它可以承受一排以上的柱子传来的荷载。联合基础最终发展成筏式(底板或满堂式)基础,在这种基础里,所有的单柱基础联合起来形成一整块钢筋混凝土板,其厚度可以变化,但通常整块的厚度相等 。

结构设计本身包括两个不同的任务:即决定主要构件尺寸和布置的结构设计;和用数学方法或图解方法或者两者并用对此结构进行分析,从而搞清楚在采用了所选特定构件的结构物中荷载是如何传递的。对于象房屋框架这样的普通结构物已经研究出许多分析方法,因而其设计和分析相对说来比较容易,可能只需进行一、二次便可完成。

但是对于任何一个异乎寻常的结构,分析和设计的工作必须要重复多次,直到经过多次计算以后才能找到一个坚固、稳定而耐久的设计。造价低廉并不属于设计的质量指标,但它却很重要,因为一个造价很高的结构物可能不会建造起来,因此设计者所得的酬金也较少。

对于城市中的典型多层结构物,无论它是计划用作办公楼或者用作住宅,工程师设计的最主要的构件是楼板,理由有二:从建筑物底层向上每层都重复出现楼板;楼板对建筑物的静荷载影响最大。事实上假设楼板是唯一的静荷载,那么静荷载就能相当精确地计算出来。

通常楼板是采用钢筋混凝土或者预应力混凝土,因为它们比钢和木材的耐火性能好,这对高层建筑来说,是一个重要的考虑因素。楼板有两种主要的型式:实心楼板和空心砖楼板(或肋形楼板)。在肋形楼板中,楼板的下半部分有一部分是空心的,这有很大的优点,因为下半部的混凝土本来对楼板不会起加强作用,只会增加自重。因而,肋形楼板比实心楼板轻得多,但要浇注具有贯穿式孔洞的肋形楼板是比较困难的,除非事先把这些孔洞十分仔细得布置好。要浇注穿过实

20

桂林理工大学本科毕业设计·论文

心楼板的孔洞时,在孔洞四周的混凝土中加设少量直径12毫米的附加钢筋,一般就可期安全。但如果时间充裕,对孔洞必须进行适当的设计。

对于大多数多层建筑来说,由于城市地价很高,所以在结构本身还处于非常初步的设计阶段时,基础就必须很快的设计出来。但是,建筑物的设计必须已经进行到至少能知道柱子的位置,从而可以确定楼板的跨度的阶段,这样就能够算出楼板的大致厚度。即使各层楼板厚度真的有所不同,也只是稍作修改,而且必须尽可能精确的把面层计算在内。一般说来,13厘米厚的密实混凝土就已足够,加上5厘米的垫层和楼板面层,总厚为18厘米。梁、柱和楼梯的重量可认为已包括在楼板的厚度内,如果楼板计划用空心砖或轻骨料建造,则板的应当减薄 。

结构重量的最初粗略计算方法如下:假设各层楼板的总面积均相同,包括一层地下室在内(地下室的地面不是悬空的,而是放在地基上)共有八层楼板,则包括屋顶在内的建筑物总静荷载,以建筑物基础每平方米计,其值为:9*18/100*2.75=4.45吨/米2。

一立方米密实混凝土还应加上活荷载值。如果这幢建筑物是住宅,则一层楼板的结构设计采用190公斤/米2的活荷载一般已经足够。比值在大多数地方当局的建筑附加法规中得到承认。但是由于所有楼板可以满载是不可能出现的,所以一般说来各地方当局从不坚持主张把此荷载都作用在基础上。在任何情况下,目前所计算的基础厚度不受附加法规的控制,因而我们可以合理地采用活荷载的任意一部分。

悬挂结构是当前最令人感兴趣的结构之一,因为最初的几个大型悬挂结构已在19xx年于伦敦或者可能还在其他大城市中建成。在所有这些结构中,柱子或支柱的数量较少而尺寸较大,以便降低对它们的压曲作用,增加其有效长度。在伦敦建成的两幢建筑物,在建筑物的中心只有一个支柱,这个支柱是一个面积约12米见方的空心混凝土塔架,它支承着设在其内部的或悬设在其壁上的电梯、楼梯、风道、管道和电缆。塔架可以称为建筑物的核心结构,在其顶部有一个向各个方向悬挑的桥,从桥上伸下高强钢筋悬吊其下面的楼板。这些钢筋很细,能够隐藏在门框或窗框里,因此就这种建筑物而言,对视线不一定有什么明显的障碍,或妨碍人们从核心部分往外向任何方向水平往来的活动。

然而,这仅仅是悬挂结构的开始,假如它能取得成功,而且假如世界上的大城市中人口仍然越来越稠密,这种设计思想将会得到发展。而纽约的那些60层摩天大楼比起世界未来城市的硕大无比的300层结构来,将是多么渺小。 看来可能而且很有可能的情景是整个城市可能就是一座或者数座这样巨大的建

21

桂林理工大学本科毕业设计·论文

筑物,这些建筑物支承在成对的1000米高的塔架上,用轻型桥梁结构连通,可能采用的是悬索桥。为了减少摆动和压曲现象,柱子将做的很大,可能不少于30米见方,而楼板所用细的高强钢吊杆悬挂于桥上,宛如悬索吊桥的桥面结构悬挂于吊索上一样。

22

桂林理工大学本科毕业设计·论文

阶段总结

经过实习后我们回到学校,开始建筑体系选型和结构体系选型以及建筑施工图的绘制,为以后结构计算作好准备。

1、建筑体系选型

建筑楼部分共有六层,高23.1m,总建筑面积6024.5m2。建筑物六层,呈L字型布局,有利于日照和自然通风。建筑造型采用倒L型的造型。建筑物主要功能区均设在南北朝向的房间内,有利于日照和自然通风,而东西向的房屋主要用于办公和会议,接待,资料收集。具体功能。建筑物立面造型方面,充分考虑运用节奏感和虚实对比的手法,讲究比例的协调,涂料色彩上面选择朴素而有内涵色系,整个办公建筑大方,简洁。其主要出入口前有供人员集散用的空地。该建筑位于十字路口,交通便利,所以设置了一个大门,2个侧门,有利于人流来往。

2、结构体系选型

在结构方面,由于层数不高,该建筑选择框架结构,因为它是由垂直混凝土柱和水平混凝土梁组成的方格形承重体系,而墙体仅起维护作用,梁与柱节点一般为刚性连接,它既能承担垂直荷载,亦能承担水平荷载。并且它的平面布置上十分灵活,可以构成丰富多变的立面造型,并且可以造成较大空间。本框架结构采用现浇的施工方式,整体性好,抗震性能强。

3、建筑施工图的绘制

我是使用天正建筑CAD,PKPM等软件进行绘图。建筑施工图包括建筑平面图,建筑立面图,建筑剖面图和建筑大样和平法施工图。在前期我们已经学习过CAD的初级运用和PKPM建模和生成平法施工图,但是有很多细节和功能都没有具体了解!在老师的指导下,我们边学边用,最终完成了施工图的绘制。

23

桂林理工大学本科毕业设计·论文

毕业实习报告

通过在桂林市临桂长岛16区和桂林市中软现代城工地的实习,我收获颇多。在各位总工的细心讲解下,我第一次全面了解了一项工程的建筑过程,并把自己在学校学到的理论知识与实践知识结合了起来,加深了对理论知识的理解。为使所学的知识有条理,在此总结如下。

11月25日到12月5日我们在桂林临桂长岛16区实习和中软现代成。 桂林市临桂县长岛16区简介:

1.工程地点:桂林市临桂县长岛16区。

2.承建单位:南宁建筑安装工程有限责任公司

建筑性质:

1.工程属于别墅,底底洋房,多层公寓为一体的复合式建筑。

2.建筑合理使用年限为50年。

3.本工程属于二类底层住宅,耐火等级为二级。

地基与基础部分:

1.基础:本工程地基为柱下独立基础,基础持力层为硬朔性红粘土,特征值为180KPA。

2.基础底板:包括底板、地梁及架空层顶板宜一次性浇成,如需分层施工必须保证结合面结合牢固。

3.一、二、三层顶板:Ⅰ段墙体图、配筋图、Ⅱ段柱心筒配筋图以及梁大样,各部分配合使用,平面尺寸留洞配梁以顶板模板图配筋图为准,墙体留洞,尺寸配筋则以墙体及核心筒图为准。

4.混凝土墙:外墙配筋按连续板配置接头位置,内墙搭接可以楼层面为准。

5.柱:主筋优先选用焊接接头每边主筋≥4根时,应分两次搭接。

6.施工缝:为调整ⅠⅡ段间差异沉降于6-7轴间设施工缝一道。

上部结构钢筋混凝土部分

1. 一般要求:

1.1 各部位混凝土强度等级:梁板二层,夹层为C30,三层为C40,四层—屋

24

桂林理工大学本科毕业设计·论文

顶为C30,柱剪力墙一层—四层C40,五层—屋面C30。

1.2 钢筋类别按图纸上布置。

1.3 钢筋混凝土结构中受力钢筋的净保护层按以下规定采用:板厚≤100mm时,为15mm;板厚>100mm时,为20mm;梁柱均为30mm且不小于受力筋的直径。

1.4 受力钢筋的接头,宜优先采用闪光对焊,电弧焊或机械连接接头,采用电弧焊时必须双面焊接,双面焊接的长度为5d,当采用搭接接头时,Ld=1.2La,La≥35d(C20),25d(C30)。

1.5凡屋面结构、卫生间以及建筑有坡度要求的部分,均需按建筑或结构平面图所示坡度要求制作,卫生间室内完成面标高之最高点必须低于卫生间以外地面,切不宜小于20mm。

2. 现浇板

2.1钢筋混凝土板分布筋,除图上特别说明者外,楼面及外露结构均用Φ6@200。

2.2 双向板的底筋,短向筋置在底层,长向筋置在短向筋上。

2.3板底受力筋伸入主梁中心线且≥5d;板上部筋应伸满支座。

2.4楼板开洞不大于300mm,若图中未特别说明,板内钢筋需从洞边绕过,不另附加钢筋。

2.5楼板开洞>300mm且≤1000mm时,孔洞每侧应附加钢筋。

3. 梁、柱、剪力墙

3.1 框架结构施工图采用平面整体表示法,一级抗震设计。

3.2 柱每边纵向钢筋不多于4根时,可在同一截面连接;每边钢筋多于4根时,应在两个截面连接,同一截面钢筋接头数量不超过接头数量的50%。

3.3框架梁支座处正负钢筋锚固长度为La≥40d(C20),30d(C30,40),次梁支座处底筋La≥15d,梁顶面筋La≥40d(C20),30d(C30,40),如采用月牙纹钢筋时,其锚固长度相应增加5d。

3.4梁内受力筋若现场搭接时,下部正筋应在支座处搭接,上部负筋应在跨中1/3跨度范围内搭接;钢筋搭接长度为1.2d。

3.5主次梁相交处,梁高较大者视为主梁,若无特殊情况次梁的负纵向筋均应分别放在主梁正纵向筋之上。

3.6纵向钢筋非焊接的搭接接头区段内箍筋间距不大于100mm及5d。

3.7钢筋混凝土柱与砖墙交接处,沿墙高每500mm在柱内先预留2Φ6钢筋与砖墙拉结,钢筋每边入墙长度为1000mm。

25

桂林理工大学本科毕业设计·论文

3.8处于后浇带的梁板,待整体结构封顶后用C40微膨胀混凝土掺加5%NSO膨胀剂浇注。三层平面及屋面接1立方米混凝土掺5kg/m3克裂速。

3.9剪力墙的墙厚及异性柱墙未注明均为200mm,地上三、四层抗震墙为底部加强部位的剪力墙。

3.10框支柱及角柱箍筋需全长加密。

12月6日到12月17日我们在奇峰小筑实习,实习总结如下:

桂林市中软现代城:

1.工程地点:南城百货南侧,会展中心西侧

2.施工单位:桂林市第八建筑安装工程公司

工程概况:

1.结构:结构为剪力墙结构,基础为筏形基础。

2.设计耐久年限为50年,耐火等级为二级。

基础部分:

1.材料:混凝土C25,筏基抗渗等级为S6,钢筋为Ⅱ级螺纹钢。

2.基础诂力层为可塑粘土,地基承载力标准值采用fk=130Kpa,基础应置于持力层内300,并用3:1砂石(每20mm分层夯实)垫至设计标高。

3.基础均设100厚C10混凝土垫层,周边伸出100。

4.基坑开挖后需进行插诂,间距2000,深5000。

5.柱与墙拉结筋垂直间距Ф6@500,伸入墙体内700。

6.基础上下板、侧壁、梁净保护层为:底层、侧壁为35mm,梁柱为25mm,顶板为15mm。

上部结构钢筋混凝土部分:

1.一般要求:

1.1墙体:采用空心砖砌筑

1.2楼梯:现浇式楼梯

1.3屋面:采用结构找坡,起坡2%

1.4内墙:厨房、卫生间采用15厚1:3水泥砂浆刮糙,要求平整,卧室、起居室、楼梯间等均15厚,1:1:6混合砂浆打底,5厚1:0.5:3混合砂浆抹面。

1.5外墙:采用12厚1:3水泥砂浆打底,8厚1:2.5水泥砂浆找平,地面素土夯实60厚,C10混凝土垫层,20厚1:3水泥砂浆找平,楼梯间、厨房、卫生间比其他房间低20,凡有地漏的地面均以I=0.5%坡向地漏。

1.6门窗:阳台为白色塑钢窗全玻璃推拉门,窗为白色塑钢推拉窗,安装时要求

26

桂林理工大学本科毕业设计·论文

窗框坐浆饱满,保护膜须清除干净,玻璃采用5mm浮法玻璃,窗台外坡5%,入户门为安全防盗门,屋面M3为镶板木门,门厅为方管钢栅门,内门按初装修要求仅预留木枕。

1.7阳台:栏板平外墙砌180厚,压顶60*300,转角外设构造柱180*180,水落管和落水斗采用Ф75PVC管。

1.8厨卫:现浇板四周做泛水120*120,用1:2水泥砂浆(掺5%防水粉)抹面,并须做灌水实验不漏后方可安装。

1.9排水:由于地处小区最低点,自排不可能,故利用底层架空层作雨水、污水、自来水三个箱体作汇水箱,雨水和污水分别用水泵排入小区排水系统,自来水加压后与小区供水系统相连,做第二加压站。

1.10沉降缝:主体建筑完成后再建门厅,以减少沉降。

结构要求:

1.受力钢筋的接头宜优先使用闪光对焊,电弧焊或机械连接接头,采用电弧焊时必须双面焊接,其焊接长度为5d,(d为焊件的最小直径)且接头数量及位置必须符合规范要求,采用搭接接头时Ld=1.2La(La≥5d)。

2.梁:伸入支座锚固长度:Ⅰ级钢Las≥15d Ⅱ级钢Las≥12d

2.1本楼不另设圈梁,楼板沿墙周边加强配筋2Φ12并与构造柱可靠连接。

2.2搁楼层屋面拱梁WLL1—5中间砖墙必须顶紧梁底,拱梁、拱板在墙支座处砖墙均应砌成台阶状,不得抹成弧形、斜形以免产生水平腿力。

3.柱:

3.1构造柱纵向钢筋采用4Φ12,箍筋间距Φ6@250且在柱上下端600范围内 加密为Φ6@150,与墙连接处应砌成马牙槎,沿墙角@500mm设2Φ6拉筋,每边伸入墙内1000mm.柱内钢筋均伸入钢筋混凝土条基础内。

3.2柱内纵向受力钢筋搭接长度为200,伸入条基底板锚固长度为500mm。

4.现浇板:

4.1钢筋混凝土板分布筋,除图上特别说明外,露面,屋面及外露结构均用Φ6@200。

4.2双向板的底筋,短向筋置于底层,长向筋置于短向筋上(基础底板除外)。

4.3板底受力钢筋伸至梁中心线且≥5d(d为直径).板上部筋应伸满支座。

4.4楼板开洞≤300mm 时.若图中未特别注明.板内钢筋须从洞边绕过.不另附加钢筋。

4.5楼板开洞>300mm且≤1000mm时,孔洞每侧应附加钢筋,面积不小于被截

27

桂林理工大学本科毕业设计·论文

钢筋的总面积且≥2Φ10.附加筋伸过洞边1.2La且伸入梁内。

总结:

实习结束了,我认为我对我所学的书本知识更加深了感性认识,并且学到了很多新东西,现归纳为几点:

1.图纸的熟悉程度大大加强。现行施工采用的都是平法施工图,对它的主要认识有:

2.标注方式:原位标注和集中标注,当原位标注和集中标注冲突时,应采用原位标注的数据。

3.对于不同符号的识读:如KZ表示框架柱,KZZ表示框支柱,YDZ表示约束边缘端柱,LL表示连梁,AL表示暗梁。

4.对于不同钢筋的识读:如Φ10@100/200(4)表示箍筋为I级钢筋,直径Φ10,加密区间距为100,非加密区间距为200,且为四肢箍。

4.1对于现场的钢筋布置有了较强的感性认识

4.2明确通长筋、底筋、腰筋的具体位置以及对它们的受力作用。

4.3明确不同钢筋的伸长尺寸不同,如梁支座上部纵筋的长度:第一排非通长筋从柱(梁)边起延伸ln/3位置,第二排非通长筋从柱(梁)边起延伸ln/4位置。

5.对于施工图纸中的钢筋代换

5.1结构构件是按强度控制时,按等强原则代换。

5.2当构件按最小配筋率,可按钢筋面积相等的原则代换。

通过实习,收获是从书本中无法得到的,尤其是对施工图的认识,对于看似复杂的钢筋,我终于有了较为系统的认识。这对我即将进行的毕业设计和将来的工作都很有帮助,尤其是对结构设计,因为我不再只是生搬课本,而可以利用这次实践增加的理性和感性认识来服务于我的设计,学习起来也不会觉得生硬。此外,我还体会到我们从事的工作是极其严谨的,容不得半点错误,丝毫疏忽都有可能引发严重的后果,所以,我们还需培养认真严谨的学习和工作态度。

总之,在实习中,我深刻的感觉到实践是对专业知识是否掌握的唯一检验标准,只有在实践中把所学的专业知识灵活运用,才能在以后的工作中得心应手。也只有在实践中学好专业规范、技术,才能为以后的工作打下良好的基础。

28

桂林理工大学本科毕业设计·论文

毕业设计总结

经过了三个月的学习我完成了大学最后一个环节毕业设计。在指导导老师的悉心指导下,我顺利的完成了毕业设计任务书所要求的各项任务,同时也受益非浅。

通过本次设计,我感觉收获很大,不仅有增强了我自己的动手能力,同时经过这次毕业设计我把以前所学的理论知识经过整理与实际结合在一起,对过去所学的知识进一步理解和掌握,而且为以后的工作、学习打下了结实的基础。四年来,因为我们是应用专业,主要是培养动手能力与实践能力,所以我们说学的知识知识面比较宽,但同时也致使了我们对工民建结构设计的专业知识的学习还不够,对很多设计细节也不甚了解。经过这次毕业设计后,无论是对结构设计还是现场施工都有了更深入的了解和体会。

同时在设计过程中对行业规范也有了一定了解,学会了如何使用规范,并在设计过程中充分考虑施工的方便性。在设计过程中采用PKPM软件进行计算,较多的使用了天正CAD和EXCEL等先进软件,给设计带来了很大的方便。但由于是第一次做一个相对完整的设计,没有设计经验,没有施工经验,在进行前面的设计环节时不能准确的预见后面可能发生的问题,造成返工等,这些都是我的弱点,我会在将来的学习、工作中不断提高,积累经验,增强自己的理论知识,并有效的和实际结合起来。

我在这次设计中也认识到了有很多不足的地方,由于对施工过程不是十分了解,有很多地方进行了简化,当然也由于时间的问题,还有很多地方没有进行设计,比如说框架柱的设计及验算。在做设计的过程中也让我养成了一个查资料的好习惯,对于自己不懂的首先要去找相关的资料来看,不但能够懂得自己要了解的知识,而且也对相关的知识有所了解,扩大了自己的知识面。